10.7 Drive Watt Loss
498 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Model
Rated Output Current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
4009 8.9 2 42 58 100
4012 11.9 2 57 84 141
4018 17.5 2 82 144 226
4023 23.4 2 108 185 293
4031 31 2 138 222 360
4038 38 2 145 270 415
4044
44 2
168 335 503
4060
59.6 2
157 444 601
4075
74.9 2
185 527 712
4089
89.2 2
212 665 877
4103
103 2 264 766 1030
4140
140 2 393 1126 1519
4168
168 2 574 1348 1922
4208
208 2 493 1465 1958
4250
250 2 686 1738 2424
4302
296 2 817 2257 3074
4371
371 2 1022 2553 3575
4414
389 2 873 2422 3295
4477
453 2 1183 3329 4512
4568
568 2 1429 3989 5418
4605
675 2 1526 4572 6098
4720
720 2 1723 5184 6907
6-Phase/12-Pulse 400 V Class
Table 10.19 Drive Watt Loss (Heavy Duty)
Model
Rated Output Current
A
Carrier Frequency
kHz
Interior Unit Loss
W
Cooling Fin Loss
W
Total Loss
W
T103
91 8
208 750 958
T140
112 5
256 912 1168
T168
150 5
352 1139 1491
T208
180 5
400 1385 1785
T250
216 5
490 1397 1887
T302
260 5
616 1985 2601
T371
304 5
638 2499 3137
T414
371 5
625 2212 2837
T477
414 2
911 2835 3746
T568
453 2
1042 3329 4371
T605
605 2
1184 4110 5294
T720
605 2
1203 4198 5401