Parameter Details
12
12.10 n: Special Adjustment
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 1023
n7-10: Pull-in Current Switching Speed
No.
(Hex.)
Name Description
Default
(Range)
n7-10
(311A)
Expert
Pull-in Current Switching
Speed
Sets the speed range to operate with the pull-in current command. Drive rated frequency = 100%
value. If there is a large quantity of oscillation when you operate in the low speed range, increase the
setting value.
10.0%
(0.0 - 100.0%)
Note:
When the drive accelerates, it enables these settings:
Motor speed n7-10 + n7-11 [Drv Mode Switch Hysteresis Band]: n8-51 [Pull-in Current @ Acceleration]
Motor speed > n7-10 + n7-11: b8-01 [Energy Saving Control Selection]
When the drive decelerates, it enables these settings:
Motor speed n7-10: n8-51 [Pull-in Current @ Acceleration]
Motor speed > n7-10: b8-01 [Energy Saving Control Selection]
If there is a large quantity of oscillation when you operate in the low speed range, increase the setting value.
When it is most important to save energy in the low speed range, decrease the setting value.
n7-11: Drv Mode Switch Hysteresis Band
No.
(Hex.)
Name Description
Default
(Range)
n7-11
(311B)
Expert
Drv Mode Switch Hysteresis
Band
Usually it is not necessary to change this setting. Sets the hysteresis level for Switching Speed set in
n7-10 [Pull-in Current Switching Speed].
5.0%
(1.0 - 20.0%)
When the speed is lower than n7-10 + n7-11 during acceleration, the drive enables pull-in current.
Note:
When the drive accelerates, it enables these settings:
Motor speed n7-10 + n7-11: n8-51 [Pull-in Current @ Acceleration]
Motor speed > n7-10 + n7-11: b8-01 [Energy Saving Control Selection]
If there is a large quantity of oscillation when you operate in the low speed range, increase the setting value.
When it is most important to save energy in the low speed range, decrease the setting value.
n7-13: Pull-in Current Switching Time
No.
(Hex.)
Name Description
Default
(Range)
n7-13
(311D)
Expert
Driving Method Switching
Time
Sets a time to enable the pull-in current commands.
100 ms
(0 - 1000 ms)
If the motor oscillates near the speed set in n7-10 [Pull-in Current Switching Speed], decrease the setting value by 20
ms.
n7-17: Resistance TemperatureCorrection
No.
(Hex.)
Name Description
Default
(Range)
n7-17
(3122)
Resistance
TemperatureCorrection
Sets the function to adjust for changes in the motor resistance value caused by changes in the
temperature.
1
(0 to 2)
0 : Invalid
1 : Valid (Only 1 time)
2 : Valid (Every time)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM