12.11 o: Keypad-Related Settings
1056 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
o5-08: Log Monitor Data 6
No.
(Hex.)
Name Description
Default
(Setting Range)
o5-08
(1558)
RUN
Log Monitor Data 6
Sets the data log monitor. This parameter is only available when using an LCD keypad.
105
(000, 101 - 999)
Note:
When A1-02 = 0 or 5 [Control Method Selection = V/f, OLV/PM], the default setting is 0.
Set the U monitor number you will log.
For example, to display U1-01 [Frequency Reference], set o5-08 = 101. When it is not necessary to set a data log monitor, set o5-08 = 000.
o5-09: Log Monitor Data 7
No.
(Hex.)
Name Description
Default
(Range)
o5-09
(1559)
RUN
Log Monitor Data 7
Sets the data log monitor. This parameter is only available when using an LCD keypad.
110
(000, 101 - 999)
Note:
Set the U monitor number you will log.
For example, to show U1-01 [Frequency Reference], set o5-09 = 101. When it is not necessary to set data log monitor, set this parameter to
000.
o5-10: Log Monitor Data 8
No.
(Hex.)
Name Description
Default
(Range)
o5-10
(155A)
RUN
Log Monitor Data 8
Sets the data log monitor. This parameter is only available when using an LCD keypad.
112
(000, 101 - 999)
Note:
Set the U monitor number you want to log.
For example, to display U1-01 [Frequency Reference], set o5-10 = 101. When it is not necessary to set a data log monitor, set this parameter
to 000.
o5-11: Log Monitor Data 9
No.
(Hex.)
Name Description
Default
(Range)
o5-11
(155B)
RUN
Log Monitor Data 9
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
Note:
Set the U monitor number you want to log.
For example, to display U1-01 [Frequency Reference], set o5-11 = 101. When it is not necessary to set a data log monitor, set this parameter
to 000.
o5-12: Log Monitor Data 10
No.
(Hex.)
Name Description
Default
(Range)
o5-12
(155C)
RUN
Log Monitor Data 10
Sets the data log monitor. This parameter is only available when using an LCD keypad.
000
(000, 101 - 999)
Note:
Set the U monitor number you want to log.
For example, to display U1-01 [Frequency Reference], set o5-12 = 101. When it is not necessary to set a data log monitor, set this parameter
to 000.
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV