EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
1078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
11.21 Defaults by Drive Model and Duty Rating ND/HD
674 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
No.
*1
Name Unit Default
- Drive Model - 2012 2018 2021 2030
C6-01
Normal /
Heavy Duty
Selection
-
HD ND HD ND HD ND HD ND
0 1 0 1 0 1 0 1
o2-04
Drive Model
(KVA)
Selection
Hex. 0066 0067 0068 006A
E2-11
(E4-11)
Motor Rated
Power
kW 2.2 3.0 3.0 3.7 3.7 5.5 5.5 7.5
b8-04
Energy Saving
Coefficient
Value
- 156.8 136.4 136.4 122.9 122.9 94.75 94.75 72.69
C5-17
(C5-37)
Motor Inertia kgm
2
0.0088 0.0158 0.0158 0.0158 0.0158 0.0255 0.026 0.037
C6-02
Carrier
Frequency
Selection
- 1 7 1 7 1 7 1 7
E2-01
(E4-01)
Motor Rated
Current (FLA)
A 8.5 11.4 11.4 14 14 19.6 19.6 26.6
E2-02
(E4-02)
Motor Rated
Slip
Hz 2.9 2.7 2.7 2.73 2.73 1.5 1.5 1.3
E2-03
(E4-03)
Motor No-
Load Current
A 3 3.7 3.7 4.5 4.5 5.1 5.1 8
E2-05
(E4-05)
Motor Line-to-
Line
Resistance
Ω 1.601 1.034 1.034 0.771 0.771 0.399 0.399 0.288
E2-06
(E4-06)
Motor
Leakage
Inductance
% 18.4 19 19 19.6 19.6 18.2 18.2 15.5
E2-10
(E4-10)
Motor Iron
Loss
W 77 91 91 112 112 172 172 262
E5-01
PM Motor
Code Selection
- 1206 1206 FFFF FFFF 1208 1208 120A 120A
L2-02
Power Loss
Ride Through
Time
s 0.5 0.5 1 1 1 1 1 1
L2-03
Minimum
Baseblock
Time
s 0.5 0.5 0.5 0.6 0.6 0.7 0.7 0.8
L2-04
Powerloss V/f
Recovery
Ramp Time
s 0.3 0.3 0.3 0.3 0.3 0.3 0.3 0.3
L2-05
Undervoltage
Detection Lvl
(Uv1)
- 190 190 190 190 190 190 190 190
L3-24
Motor Accel
Time @ Rated
Torque
s 0.145 0.145 0.145 0.154 0.154 0.168 0.168 0.175
L8-02
Overheat
Alarm Level
°C 124 124 110 110 110 110 110 110
L8-09
Output Ground
Fault
Detection
- 1 1 1 1 1 1 1 1
L8-38
Carrier
Frequency
Reduction
- 2 2 2 2 2 2 2 2
n1-01
Hunting
Prevention
Selection
- 1 1 1 1 1 1 1 1
n1-03
Hunting
Prevention
Time Constant
ms 10 10 10 10 10 10 10 10