EasyManua.ls Logo

YASKAWA GA800

YASKAWA GA800
1078 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12.7 F: Options
844 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
F1-19: Deviation 4 Detection Selection
No.
(Hex.)
Name Description
Default
(Range)
F1-19
(03AE)
Deviation 4 Detection
Selection
Sets the number of pulses necessary to cause dv4 [Inversion Prevention Detection].
128
(0 - 5000)
The drive detects a dv4 [Inversion Prevention Detection] faultwhen the pulses in a reverse direction to the speed
reference are input for longer than the time set in F1-19.
Note:
Refer to the E5-11 [Encoder Z-Pulse Offset] value and the Δθ value shown on the motor nameplate. An incorrect E5-11 value will
frequently be the cause of a dv4 fault.
When you use the drive in an application that rotates the motor from the load side in the reverse direction of the speed reference, set F1-19
= 0.
F1-20: Encoder 1 PCB Disconnect Detect
No.
(Hex.)
Name Description
Default
(Range)
F1-20
(03B4)
Encoder 1 PCB Disconnect
Detect
Sets the function that enables and disables detection of a disconnected encoder connection cable to
cause PGoH [Encoder (PG) Hardware Fault].
1
(0, 1)
0 : Disabled
1 : Enabled
F1-21: Encoder 1 Signal Selection
No.
(Hex.)
Name Description
Default
(Range)
F1-21
(03BC)
Encoder 1 Signal Selection
Sets the number of channels for the signal to the encoder option card.
0
(0, 1)
0 : A Pulse Detection
1 : AB Pulse Detection
F1-30: Motor 2 Encoder PCB Port Select
No.
(Hex.)
Name Description
Default
(Range)
F1-30
(03AA)
Motor 2 Encoder PCB Port
Select
Sets the drive port to install the motor 2 encoder option card.
1
(0, 1)
0 : CN5-C
One option card receives the speed feedback signals from motor 1 and motor 2.
1 : CN5-B
Two option cards receive the speed feedback signals from motor 1 and motor 2.
F1-31: Encoder 2 Pulse Count (PPR)
No.
(Hex.)
Name Description
Default
(Range)
F1-31
(03B0)
Encoder 2 Pulse Count
(PPR)
Sets the number of output pulses for each motor revolution for motor 2.
1024 ppr
(1 - 60000 ppr)
F1-32: Encoder 2 Rotation Selection
No.
(Hex.)
Name Description
Default
(Range)
F1-32
(03B1)
Encoder 2 Rotation Selection
Sets the output sequence for the A and B pulses from the encoder for motor 2. This parameter
assumes that the motor is operating in the forward direction.
0
(0, 1)
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV

Table of Contents