Parameter Details
12
12.7 F: Options
YASKAWA SIEPC71061737D GA800 Drive Technical Reference 879
F7-65: PZD6 Write
No.
(Hex.)
Name Description
Default
(Range)
F7-65
(0785)
PZD6 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD6 (PPO output). A
value of 0, 1, or 2 will disable the PZD6 (PPO output) write operation to the MEMOBUS/Modbus
register.
0
F7-66: PZD7 Write
No.
(Hex.)
Name Description
Default
(Range)
F7-66
(0786)
PZD7 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD7 (PPO output). A
value of 0, 1, or 2 will disable the PZD7 (PPO output) write operation to the MEMOBUS/Modbus
register.
0
F7-67: PZD8 Write
No.
(Hex.)
Name Description
Default
(Range)
F7-67
(0787)
PZD8 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD8 (PPO output). A
value of 0, 1, or 2 will disable the PZD8 (PPO output) write operation to the MEMOBUS/Modbus
register.
0
F7-68: PZD9 Write
No.
(Hex.)
Name Description
Default
(Range)
F7-68
(0788)
PZD9 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD9 (PPO output). A
value of 0, 1, or 2 will disable the PZD9 (PPO output) write operation to the MEMOBUS/Modbus
register.
0
F7-69: PZD10 Write
No.
(Hex.)
Name Description
Default
(Range)
F7-69
(0789)
PZD10 Write
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD10 (PPO output). A
value of 0, 1, or 2 will disable the PZD10 (PPO output) write operation to the MEMOBUS/Modbus
register.
0
F7-70: PZD1 Read (Status Word)
No.
(Hex.)
Name Description
Default
(Range)
F7-70
(078A)
PZD1 Read (Status Word)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD1 (PPO input). PZD1
(PPO input) functions as the ZSW when F7-70 = 0.
0
F7-71: PZD2 Read (Output Frequency)
No.
(Hex.)
Name Description
Default
(Range)
F7-71
(078B)
PZD2 Read (Output
Frequency)
When you use a Profibus option, sets the MEMOBUS/Modbus address for PZD2 (PPO input). PZD2
(PPO input) functions as the HIW when F7-71 = 0.
0
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV
V/f
CL-V/f
OLV
CLV
AOLV
OLV/PM OLV/PM
AOLV/PM
CLV/PM
EZOLV