12.8 H: Terminal Functions
952 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
H6-05: Terminal RP Filter Time
No.
(Hex.)
Name Description
Default
(Range)
H6-05
(0430)
RUN
Terminal RP Filter Time
Sets the time constant for the pulse train input primary delay filters.
0.10 s
(0.00 - 2.00 s)
H6-06: Terminal MP Monitor Selection
No.
(Hex.)
Name Description
Default
(Range)
H6-06
(0431)
RUN
Terminal MP Monitor
Selection
Sets a function for pulse train monitor output terminal MP. Sets the x-xx part of the Ux-xx monitor.
102
(000, 031, 101, 102, 105,
116, 501, 502, 801 - 809,
821 - 825, 831 - 839, 851 -
855)
Note:
To use in through mode or when terminal MP is not used, set this parameter to 000 or 031.
When you use the pulse train monitor, make sure that you connect peripheral devices as specified by these load
conditions:
Incorrect connections can make the characteristics not sufficient or cause mechanical damage.
Use the pulse train monitor as the sourcing output.
Output Voltage
VRL(V)
Load Impedance (kΩ)
5 V or more 1.5 or more
8 V or more 4.0 or more
10 Vor more 10 or more
Figure 12.115 Circuit Diagram When Used as the Sourcing Output
Use the pulse train monitor as the sinking input
External Power Supply (V) 12 VDC ± 10%, 15 VDC ± 10%
Sinking current (mA) 16 mA or less
Figure 12.116 Circuit Diagram When Used as the Sinking Input