12.8 H: Terminal Functions
954 YASKAWA SIEPC71061737D GA800 Drive Technical Reference
Figure 12.118 Virtual Digital I/O Functional Block Diagram
Note:
• Refer to H1-xx Multi-Function Digital Input Setting Values on page 885 for more information on the virtual digital input setting values.
• Refer to H2-xx MFDO Setting Values on page 914 for more information on the virtual digital output setting values.
• Refer to H3-xx Multi-Function Analog Input Terminal Settings on page 936 for more information on the virtual analog input setting values.
• Refer to H4-xx H4: Analog Outputs on page 942 for more information on the virtual analog output setting values.
• You cannot set 0 [3-Wire Sequence] and 20 or 2F [External Fault] to H7-01 to H7-04 [Virtual Multi-Function Input 1 to 4].
• When you will not use the terminal, set H7-01 to H7-04 = F. The through mode function is not supported.
• You cannot use the virtual I/O function selection and the multi-function input for DI-A3 at the same time.
■ H7-00: Virtual MFIO selection
No.
(Hex.)
Name Description
Default
(Range)
H7-00
(116F)
Expert
Virtual MFIO selection
Sets the function to enable and disable the virtual I/O function. Set this parameter to 1 to operate the
virtual I/O function.
0
(0, 1)
0 : Disabled
1 : Enabled
■ H7-01: Virtual Multi-Function Input 1
No.
(Hex.)
Name Description
Default
(Range)
H7-01
(1185)
Expert
Virtual Multi-Function Input
1
Sets the function that enters the virtual input set in H7-10 [Virtual Multi-Function Output 1].
F
(1 - 19F)
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
■ H7-02: Virtual Multi-Function Input 2
No.
(Hex.)
Name Description
Default
(Range)
H7-02
(1186)
Expert
Virtual Multi-Function Input
2
Sets the function that enters the virtual input set in H7-12 [Virtual Multi-Function Output 2].
F
(1 - 19F)
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
■ H7-03: Virtual Multi-Function Input 3
No.
(Hex.)
Name Description
Default
(Range)
H7-03
(1187)
Expert
Virtual Multi-Function Input
3
Sets the function that enters the virtual input set in H7-14 [Virtual Multi-Function Output 3].
F
(1 - 19F)
Note:
1B [Programming Lockout] and 11B [Inverse Input of 1B] are not available.
H7-01
[Virtual Multi-Function
Input 1]
H7-11
[Virtual Output
1 Delay Time]
H7-10
[Virtual Multi-Function
Output 1]