Parameter Details
12
12.4 d: References
YASKAWA SIEPYEULA5001C LA500 Technical Manual 297
d1-07: Speed Reference 7
No.
(Hex.)
Name Description
Default
(Range)
d1-07
(0286)
RUN
Speed Reference 7
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
0.00 Hz
(0.00 - 120.00 Hz)
d1-08: Speed Reference 8
No.
(Hex.)
Name Description
Default
(Range)
d1-08
(0287)
RUN
Speed Reference 8
Sets the Speed reference in the units from o1-03 [Frequency Display Unit Selection].
0.00 Hz
(0.00 - 120.00 Hz)
d1-18: Spd Ref Sel Mode
No.
(Hex.)
Name Description
Default
(Range)
d1-18
(02C0)
Spd Ref Sel Mode
Sets the priority of the speed reference digital inputs.
1
(0 - 2)
0 : Use Multi-Speed references d1-01 to d1-08
Up to eight separate preset speed references can be programmed to the drive using parameters d1-01 through d1-
08 and can be selected using binary coded digital inputs. When d1-18 = 0, parameters d1-19 through d1-23 are
not displayed.
1 : High speed reference has priority
Six different speeds (d1-19 to d1-23, d1-26) can be programmed to the drive and can be selected using dedicated
digital inputs. Each of the speed references set to d1-19 through d1-23 takes priority over the leveling speed set to
d1-26. When d1-18 = 1, parameter d1-01 to d1-08 are not displayed.
2 : Leveling speed reference has priority
Six different speeds (d1-19 to d1-23, d1-26) can be programmed to the drive and can be selected using dedicated
digital inputs. The leveling speed reference in d1-26, however, takes priority over all other speed references when
enabled via one of the multi-function input terminals [H1-xx = 53]. When d1-18 = 2, parameters d1-01 to d1-08
are not displayed.
d1-19: Nominal Speed
No.
(Hex.)
Name Description
Default
(Range)
d1-19
(02C1)
RUN
Nominal Speed
Sets the speed reference when multi-function input Nominal Speed is on.
50.00 Hz
(0.00 - 120.00 Hz)
d1-20: Intermed Speed 1
No.
(Hex.)
Name Description
Default
(Range)
d1-20
(02C2)
RUN
Intermed Speed 1
Sets the speed reference when intermediate speed 1 is selected by digital inputs.
0.00 Hz
(0.00 - 120.00 Hz)
d1-21: Intermed Speed 2
No.
(Hex.)
Name Description
Default
(Range)
d1-21
(02C3)
RUN
Intermed Speed 2
Sets the speed reference when intermediate speed 2 is selected by digital inputs.
0.00 Hz
(0.00 - 120.00 Hz)
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV
V/f
OLV

Table of Contents