10 - 8 DS8108 Digital Scanner Product Reference Guide
Snapshot Mode Timeout
Parameter # 323
SSI # F0h 43h
This parameter sets the amount of time the imager remains in Snapshot Mode. The imager exits Snapshot Mode
when you press the trigger, or when the Snapshot Mode Timeout elapses. To set this timeout value, scan the Set
Snapshot Mode Timeout bar code, and then scan a bar code from Appendix B, Numeric Bar Codes. The default
value is 0 which represents 30 seconds; values increment by 30. For example, 1 = 60 seconds, 2 = 90 seconds.
To quickly re-set the default timeout to 30 seconds, scan the 30 Seconds bar code.
If you scan No Timeout, the imager remains in Snapshot Mode until you press the trigger.
Set Snapshot Mode Timeout
*30 Seconds
No Timeout