Data Capture 2 - 3
Low/low beeps Green Alphanumeric expected. Enter another alphanumeric
character or scan the
End of Message
bar code.
High/high beeps Green blinking ADF criteria or action is expected. Enter another
criteria or action or scan the
Save Rule
bar code.
High/low/low beeps Green All criteria or actions cleared for current rule, continue
entering rule.
High/low/high/low beeps Green
(turns off blinking)
Rule saved. Rule entry mode exited.
Long low/long high beeps Red Rule error. Entry error, wrong bar code scanned, or
criteria/action list is too long for a rule. Re-enter
criteria or action.
Low beep Green Deleted last saved rule. The current rule is left intact.
Low/high/high beeps Green All rules deleted.
Long low/long high/long
low/long high beeps
Red Out of rule memory. Erase some existing rules, then
try to save rule again.
Long low/long high/long
low beeps
Green
(turns off blinking)
Cancel rule entry. Rule entry mode exited because of
an error or the user asked to exit rule entry.
Host Specific
USB only
Four high beeps None
Digital
scanner has not completed initialization. Wait
several seconds and scan again.
RS-232 only
High/high/high/low beeps Red RS-232 receive error.
High beep None A <BEL> character is received when Beep on <BEL>
is enabled (Point-to-Point mode only).
Table 2-1 Digital Scanner Beeper and LED Indications (Continued)
Beeper Sequence LED Indication