IES-2000/3000 User’s Guide
23-4 SNMP Configuration
Table 23-3 SNMP Traps
GENERIC TRAP SPECIFIC TRAP DESCRIPTION
4 (TRAP_OVERHEATOVER) This trap is sent when the temperature returns to
normal.
For example, the following trap shows that the current
reading at Temp1 is 64 degrees centigrade.
"Temp1 back to Normal (Limit = 65 degree C, Read =
64 degree C)"
5 (TRAP_ERRLOG) This trap is sent when an error log is recorded in the
system. The trap includes the content of the error log.
8 (TRAP_VOLTAGELOW) This trap is sent when the voltage falls out of the
tolerance range.
For example, the following trap shows that the current
reading at the 3.3V sensor is 3.00V, the upper voltage
limit is 3.36V and the lower voltage limit is 3.10V.
"Power 3.3V exceeds Limit (Up Limit = 3.36V, Down
Limit = 3.10V, Read = 3.00V)"
9 (TRAP_POWENORMAL) This trap is sent when the voltage returns to normal.
For example, the following trap shows that the current
reading at the 3.3V sensor is 3.20V, the upper voltage
limit is 3.36V and the lower voltage limit is 3.10V.
"Power 3.3V back to Normal (Up Limit = 3.36V, Down
Limit = 3.10V, Read = 3.20V)"