Chapter 3 Hardware, Interfaces and Zones
ZyWALL/USG Series User’s Guide
63
Note: Use an 8-wire Ethernet cable to run your Gigabit Ethernet connection at 1000
Mbps. Using a 4-wire Ethernet cable limits your connection to 100 Mbps. Note that
the connection speed also depends on what the Ethernet device at the other end
can support.
3.2 Mounting
Some models can be mounted in a rack, and some can be mounted on a wall.
3.2.1 Rack-mounting
See Table 16 on page 63 for the ZyWALL/USG models that can be rack mounted. Use the following
steps to mount the ZyWALL/USG on an EIA standard size, 19-inch rack or in a wiring closet with
other equipment using a rack-mounting kit. Make sure the rack will safely support the combined
weight of all the equipment it contains and that the position of the ZyWALL does not make the rack
unstable or top-heavy. Take all necessary precautions to anchor the rack securely before installing
the unit.
Note: Leave 10 cm of clearance at the sides and 20 cm in the rear.
Use a #2 Phillips screwdriver to install the screws.
Note: Failure to use the proper screws may damage the unit.
1 Align one bracket with the holes on one side of the ZyWALL/USG and secure it with the included
bracket screws (smaller than the rack-mounting screws).
2 Attach the other bracket in a similar fashion.
Table 16 Mounting Method
RACK-MOUNTING WALL-MOUNTING
ZyWALL 110 USG40
ZyWALL 310 USG40W
ZyWALL 1100 USG60
USG110 USG60W
USG210 USG20-VPN
USG310 USG20W-VPN
USG1100
USG1900
USG2200-VPN