The data output message starts with MEASUREMENT followed by Product Number, Serial Number (tabulator
between). The rest of the message is the output parameters which change from record to record. The parameter names
and values are separated by tabulator (ASCII code 09).
6.8 Output parameters provided by the ZPulse
®
These data are output as a string from the sensor in Smart Sensor Terminal mode. The name with unit shown in the
table 5-2 is the exact same way as these are sent from the sensor, i.e. parameter name with unit in [ ] parentheses. The
parameter name and the value output are separated by a tabulator (ASCII code 09). The output is a long string
terminated by carriage return + line feed after all the profile data at the end. Each parameter can be read with a Get
command using the RS-232 Protocol
Table 6-3: Overview of available data parameters for ZPulse
TM
DCS 4420/4830/4520/4930
Abs speed The average absolute speed from the orthogonal current vectors (vector averaged).
Direction The current direction, i.e. the direction of the absolute speed vector referenced to magnetic
north.
North North current speed vector.
East East current speed vector.
The last measured compass heading.
Tilt X The last measured tilt x.
Tilt Y The last measured tilt y.
SP std Single ping standard deviation, i.e. the standard deviation of all speed measurements (ping) in
an interval.
Ping count Number of ping performed in an interval.
Abs Tilt Absolute sensor tilt (ref horizontal plane) during a recording interval.
Max Tilt Maximum sensor tilt (ref horizontal plane) during a recording interval.
Standard deviation of sensor tilt during a recording interval.
Temperature NB! Available for ZPulse
TM
DCS version 4830/4930.
Strength X Signal strength, X-axis: available parameter if axis strength is enabled.
Strength Y Signal strength, Y-axis: available parameter if axis strength is enabled.
Strength X Trd1 Signal strength, X-axis Transducer 1: available parameter if transducer strength is enabled.
Strength X Trd3 Signal strength, X-axis Transducer 3: available parameter if transducer strength is enabled.
Strength Y Trd2 Signal strength, Y-axis Transducer 2: available parameter if transducer strength is enabled.
Strength Y Trd4 Signal strength, Y-axis Transducer 4: available parameter if transducer strength is enabled.