EasyManua.ls Logo

ABB ACS880 N5700 Series - Page 138

ABB ACS880 N5700 Series
662 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
- / -U-phase rms current. For scaling, see parameter 46.5.0.00 ... 30000.00 A
- / real32V-phase rms current.V-phaseRMScurrent1.73
- / -V-phase rms current. For scaling, see parameter 46.5.0.00 ... 30000.00 A
- / real32W-phase rms current.W-phase RMS
current
1.74
- / -W-phase rms current. For scaling, see parameter 46.5.0.00 ... 30000.00 A
- / real32
(Only visible when IGBT supply unit control activated
by
95.20
)
Estimated line current flowing through the supply unit.
Line current1.102
- / -Estimated line current. For scaling, see parameter 46.5.0.00 ... 30000.00 A
- / real32
(Only visible when IGBT supply unit control activated
by
95.20
)
Estimated active current flowing through the supply
unit.
Active current1.104
- / -Estimated active current. For scaling, see parameter
46.5.
-30000.00 ...
30000.00 A
- / real32
(Only visible when IGBT supply unit control activated
by
95.20
)
Estimated reactive current flowing through the supply
unit.
Reactive current1.106
- / -Estimated reactive current. For scaling, see parameter
46.5.
-30000.00 ...
30000.00 A
- / real32
(Only visible when IGBT supply unit control activated
by
95.20
)
Estimated frequency of the power supply network.
Grid frequency1.108
- / -Estimated supply frequency. For scaling, see parameter
46.2.
0.00 ... 100.00 Hz
- / real32
(Only visible when IGBT supply unit control activated
by
95.20
)
Estimated voltage of the power supply network.
Grid voltage1.109
10 = 1 V / 100 = 1 VEstimated supply voltage.0.00 ... 2000.00 V
- / real32
(Only visible when IGBT supply unit control activated
by
95.20
)
Estimated apparent power being transferred through
the supply unit.
Grid apparent power1.110
- / -Estimated apparent power. For scaling, see parameter
46.4.
-30000.00 ...
30000.00 kVA
- / real32
(Only visible when IGBT supply unit control activated
by
95.20
)
Estimated power being transferred through the supply
unit.
Grid power1.112
- / -Estimated supply power. For scaling, see parameter
46.4.
-30000.00 ...
30000.00 kW
138 Parameters

Table of Contents