Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
43.5 FB A reference 1 (page 140).FB A ref1
53.6 FB A reference 2 (page 140).FB A ref2
83.9 EFB reference 1 (page 140).EFB ref1
93.10 EFB reference 2 (page 140).EFB ref2
103.11 DDCS controller ref 1 (page 140).DDCS ctrl ref1
113.12 DDCS controller ref 2 (page 140).DDCS ctrl ref2
123.13 M/F or D2D ref1 (page 141).M/F reference 1
133.14 M/F or D2D ref2 (page 141).M/F reference 2
15ReservedMotor
potentiometer
16Not in use.PID
18Control panel reference, with initial value from last-used
panel reference. See section Using the control panel as
an external control source (page 25).
Control panel (ref
saved)
19Control panel reference, with initial value from previous
source or actual value. See section Using the control
panel as an external control source (page 25).
Control panel (ref
copied)
See Terms and abbreviations (page 130).Other [value]
Zero / uint32Selects torque reference source 2.
For the selections, and a diagram of reference source
selection, see parameter 26.11 Torque ref1 source.
Torque ref2 source26.12
Ref1 / uint16Selects a mathematical function between the reference
sources selected by parameters 26.11 Torque ref1
source and 26.12 Torque ref2 source. See diagram at
26.11 Torque ref1 source.
Torque ref1 function26.13
0Signal selected by 26.11 Torque ref1 source is used as
torque reference 1 as such (no function applied).
Ref1
1The sum of the reference sources is used as torque
reference 1.
Add (ref1 + ref2)
2The subtraction ([26.11 Torque ref1 source] - [26.12
Torque ref2 source]) of the reference sources is used
as torque reference 1.
Sub (ref1 - ref2)
3The multiplication of the reference sources is used as
torque reference 1.
Mul (ref1 x ref2)
4The smaller of the reference sources is used as torque
reference 1.
Min (ref1, ref2)
5The greater of the reference sources is used as torque
reference 1.
Max (ref1, ref2)
Torque reference 1 /
uint32
Configures the selection between torque references 1
and 2.
See diagram at 26.11 Torque ref1 source.
0 = Torque reference 1
1 = Torque reference 2
Torque ref1/2
selection
26.14
00.Torque reference 1
298 Parameters