Def / Type
FbEq 16b / 32b
DescriptionName / Range /
Selection
No.
1 = 1 A / 100 = 1 AMotor current at peak.-32768.00 ...
32767.00 A
- / real32Displays the voltage in the intermediate DC circuit of
the drive at the moment the peak value was recorded.
PVL DC voltage at
peak
36.14
10 = 1 V / 100 = 1 VDC voltage at peak.0.00 ... 2000.00 V
- / real32Displays the motor speed at the moment the peak value
was recorded.
PVL speed at peak36.15
- / -Motor speed at peak. For scaling, see parameter 46.1.-32768.00 ...
32767.00 rpm
0 / uint16Displays the date on which the peak value logger was
last reset.
PVL reset date36.16
0 / uint32Displays the time at which the peak value logger was
last reset.
PVL reset time36.17
1 = 1Last reset time of the peak value logger.00:00:00…23:59:59
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that were below 10%. Note that this
percentage also includes the samples that had a
negative value.
AL1 below 10%36.20
1 = 1 % / 100 = 1 %Amplitude logger 1 samples below 10%.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 10 and 20 %.
AL1 10 to 20%36.21
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 10 and 20 %.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 20 and 30 %.
AL1 20 to 30%36.22
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 20 and 30 %.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 30 and 40 %.
AL1 30 to 40%36.23
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 30 and 40 %.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 40 and 50 %.
AL1 40 to 50%36.24
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 40 and 50 %.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 50 and 60 %.
AL1 50 to 60%36.25
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 50 and 60 %.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 60 and 70 %.
AL1 60 to 70%36.26
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 60 and 70 %.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 70 and 80 %.
AL1 70 to 80%36.27
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 70 and 80 %.0.00 ... 100.00 %
- / real32Displays the percentage of samples recorded by
amplitude logger 1 that fall between 80 and 90 %.
AL1 80 to 90%36.28
1 = 1 % / 100 = 1 %Amplitude logger 1 samples between 80 and 90 %.0.00 ... 100.00 %
Parameters 357