Parameters and firmware blocks
157
-8…8 Scaling factor for speed reference 1/2.
24.07 SPEEDREF NEG ENA FW block: SPEED REF MOD (see above)
Selects the source for the speed reference inversion. 1 = Sign of the speed reference is changed
(inversion active).
Bit pointer: Group, index and bit
24.08 CONST SPEED FW block: SPEED REF MOD (see above)
Defines the constant speed.
-30000…30000 rpm Constant speed.
24.09 CONST SPEED ENA FW block: SPEED REF MOD (see above)
Selects the source for enabling the use of the constant speed reference define by parameter 24.08
CONST SPEED. 1 = Enable.
Bit pointer: Group, index and bit
24.10 SPEED REF JOG1 FW block: SPEED REF MOD (see above)
Defines the speed reference for jogging function 1. See section Jogging on page 50.
-30000…30000 rpm Speed reference for jogging 1.
24.11 SPEED REF JOG2 FW block: SPEED REF MOD (see above)
Defines the speed reference for jogging function 2. See section Jogging on page 50.
-30000…30000 rpm Speed reference for jogging 2.
24.12 SPEED REFMIN ABS FW block: SPEED REF MOD (see above)
Defines the absolute minimum limit for the speed reference.
0…30000 rpm Absolute minimum limit for speed reference.
Limited speed reference
Speed reference
20.01 MAXIMUM SPEED
–(24.12 SPEED REFMIN ABS
24.12 SPEED REFMIN ABS
20.02 MINIMUM SPEED

Table of Contents