Parameters and firmware blocks
207
50.06 FBA ACT1 TR SRC FW block: FIELDBUS (see above)
Selects the source for fieldbus actual value 1 when parameter 50.04 FBA REF1 MODESEL / 50.05
FBA REF2 MODESEL is set to (0) Raw data.
Value pointer: Group and index
50.07 FBA ACT2 TR SRC FW block: FIELDBUS (see above)
Selects the source for fieldbus actual value 2 when parameter 50.04 FBA REF1 MODESEL / 50.05
FBA REF2 MODESEL is set to (0) Raw data.
Value pointer: Group and index
50.08 FBA SW B12 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 28 (2.13 FBA MAIN SW bit 28).
Note that this functionality may not be supported by the fieldbus communication profile.
Bit pointer: Group, index and bit
50.09 FBA SW B13 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 29 (2.13 FBA MAIN SW bit 29).
Note that this functionality may not be supported by the fieldbus communication profile.
Bit pointer: Group, index and bit
50.10 FBA SW B14 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 30 (2.13 FBA MAIN SW bit 30).
Note that this functionality may not be supported by the fieldbus communication profile.
Bit pointer: Group, index and bit
50.11 FBA SW B15 SRC FW block: FIELDBUS (see above)
Selects the source for freely programmable fieldbus status word bit 31 (2.13 FBA MAIN SW bit 31).
Note that this functionality may not be supported by the fieldbus communication profile.
Bit pointer: Group, index and bit