EasyManua.ls Logo

ABB ACSM1 - Page 210

ABB ACSM1
510 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameters and firmware blocks
210
51.30 MAPPING FILE VER FW block: None
Displays the fieldbus adapter module mapping file revision stored in the memory of the drive.
In hexadecimal format. Example: 0x107 = revision 1.07.
51.31 D2FBA COMM STA FW block: None
Displays the status of the fieldbus adapter module communication.
(0) IDLE Adapter not configured.
(1) EXEC. INIT Adapter initializing.
(2) TIME OUT A timeout has occurred in the communication between the adapter
and the drive.
(3) CONFIG ERROR Adapter configuration error – the major or minor revision code of the
common program revision in the fieldbus adapter module is not the
revision required by the module (see par. 51.32 FBA COMM SW
VER), or mapping file upload has failed more than three times.
(4) OFF-LINE Adapter is off-line.
(5) ON-LINE Adapter is on-line.
(6) RESET Adapter is performing a hardware reset.
51.32 FBA COMM SW VER FW block: None
Displays the common program revision of the adapter module.
In format axyz, where a = major revision number, xy = minor revision numbers. z = correction letter.
Example: 190A = revision 1.90A.
51.33 FBA APPL SW VER FW block: None
Displays the application program revision of the adapter module.
In format axyz, where: a = major revision number, xy = minor revision numbers, z = correction letter.
Example: 190A = revision 1.90A.