Parameters and firmware blocks
216
57.09 KERNEL SYNC MODE FW block: D2D COMMUNICATION (see above)
Determines which signal the time levels of the drive are synchronised with. An offset can be defined
by parameter 57.10 KERNEL SYNC OFFS if desired.
(0) NoSync No synchronisation.
(1) D2DSync If the drive is the master on a drive-to-drive link, it broadcasts a
synchronisation signal to the follower(s). If the drive is a follower, it
synchronises its firmware time levels to the signal received from the
master.
(2) FBSync The drive synchronises its firmware time levels to a synchronisation
signal received through a fieldbus adapter.
(3) FBToD2DSync If the drive is the master on a drive-to-drive link, it synchronises its
firmware time levels to a synchronisation signal received from a
fieldbus adapter, and broadcasts the signal on the drive-to-drive link. If
the drive is a follower, this setting has no effect.
57.10 KERNEL SYNC OFFS FW block: D2D COMMUNICATION (see above)
Defines an offset in microseconds between the synchronisation signal received and the time levels of
the drive. With a positive value, the drive time levels will lag behind the synchronisation signal; with a
negative value, the drive time levels will lead.
-4999…5000 us Synchronisation offset.
57.11 REF 1 MSG TYPE FW block: D2D COMMUNICATION (see above)
By default, in drive-to-drive communication, the master broadcasts the drive-to-drive control word and
references 1 and 2 to all followers. This parameter enables multicasting, ie, sending the drive-to-drive
control word and reference 1 to a certain drive or group of drives. The message can then be further
relayed to another group of drives to form a multicast chain.
In the master, as well as any submaster (ie, follower relaying the message to other followers), the
sources for the control word and reference 1 are selected by parameters 57.08 FOLLOWER CW SRC
and 57.06 REF 1 SRC respectively.
Note: Reference 2 is broadcast by the master to all followers.
For more information, see Appendix B – Drive-to-drive link on page 431.
(0) Broadcast The control word and reference 1 are sent by the master to all
followers. If the master has this setting, the parameter has no effect in
the followers.
(1) Ref1 MC Grps The drive-to-drive control word and reference 1 are only sent to the
drives in the multicast group specified by parameter 57.13 NEXT
REF1 MC GRP. This setting can also be used in submasters
(followers in which parameters 57.03 NODE ADDRESS and 57.12
REF1 MC GROUP are set to the same value) to form a multicast
chain.