Parameters and firmware blocks
226
62.11 PRESET MODE FW block: PRESET (see above)
Selects the preset mode.
Presets are used to set the position system to a parameter value (preset position) or actual position.
The physical position of the driven machinery is not changed, but the new position value is used as
home position.
Note: Selections 1…3 can also be activated by the homing start command (source selected by
parameter 62.03 HOMING START).
(0) Disabled Preset mode not in use.
(1) Synch Ref Synchron reference chain (parameter group 68) is set to the value of
the preset position (62.13 PRESET POSITION).
(2) Act to Synch Synchron reference chain (parameter group 68) is set to the value of
the actual position (1.12 POS ACT).
(3) Whole system Position system (parameter groups 60, 66, 68, 70 and 71) is set to the
value of the preset position (62.13 PRESET POSITION).
62.12 PRESET TRIG FW block: PRESET (see above)
Selects the source for the preset mode start signal.
(0) Homing start The homing start signal (selected by parameter 62.03 HOMING
START) also activates the selected preset mode.
(1) ENC1 DI1 _– Rising edge of encoder 1 digital input DI1.
(2) ENC1 DI1 –_ Falling edge of encoder 1 digital input DI1.
(3) ENC1 DI2 _– Rising edge of encoder 1 digital input DI2.
(4) ENC1 DI2 –_ Falling edge of encoder 1 digital input DI2.
(5) Reserved.
(6) ENC1 Zerop Rising edge of encoder 1 zero pulse.
(7) ENC2 DI1 _– Rising edge of encoder 2 digital input DI1.
(8) ENC2 DI1 –_ Falling edge of encoder 2 digital input DI1.
(9) ENC2 DI2 _– Rising edge of encoder 2 digital input DI2.
(10) ENC2 DI2 –_ Falling edge of encoder 2 digital input DI2.
(11) Reserved.
(12) ENC2 Zerop Rising edge of encoder 2 zero pulse.
(13) PROBE1 SW Trigger probe 1 signal (selected by parameter 62.22 TRIG PROBE1
SW) also activates the selected preset mode.
(14) PROBE2 SW Trigger probe 2 signal (selected by parameter 62.23 TRIG PROBE2
SW) also activates the selected preset mode.