Parameters and firmware blocks
245
67.01 SYNC REF SEL FW block: SYNC REF SEL (see above)
Selects the source for the position reference in synchron control.
(0) ZERO Zero position reference.
(1) AI1 Analogue input 1.
(2) AI2 Analogue input 2.
(3) FBA REF1 Fieldbus reference 1.
(4) FBA REF2 Fieldbus reference 2.
(5) D2D REF1 Drive-to-drive reference 1.
(6) D2D REF2 Drive-to-drive reference 2.
(7) Reserved.
(8) POS 2ND ENC Encoder 2.
(9) VIRT MAST Virtual master reference selected by parameter 67.02 VIRT MAS REF
SEL.
67.02 VIRT MAS REF SEL FW block: SYNC REF SEL (see above)
Selects the source for the virtual master speed reference.
(0) ZERO Zero position reference.
(1) AI1 Analogue input 1.
(2) AI2 Analogue input 2.
(3) FBA REF1 Fieldbus reference 1.
(4) FBA REF2 Fieldbus reference 2.
(5) D2D REF1 Drive-to-drive reference 1.
(6) D2D REF2 Drive-to-drive reference 2.
(7) ENC1 SPEED Encoder 1.
(8) ENC2 SPEED Encoder 2.
(9) VM SPD REF Parameter 67.10 VIRT MAS SPD REF.