When you order an Advant Controller 450, you select the desired function repertoire from a
library of program modules. These modules are factory assembled into a program card.
Available standard program modules with function library follow.
Basic functions (always included):
QC07-BAS41 Basic system
(QC07-BOB41 Boot block).
Additional functions:
QC07-LIB41 Additional PC elements 1
QC07-LIB42 Additional PC elements 2
QC07-FUZ41 Fuzzy control
QC07-LOS41 MasterView 320
QC07-OPF41 Operator functions support
QC07-BAT41 MasterBatch 200/1 support
QC07-UDP41 User defined PC Elements
QC07-COM41 Object support via Advant Fieldbus 100.
Examples of other optional functions requiring extra hardware are redundant CPU,
communication between controllers, positioning, digital input, and so on.
3URGXFW9DULDQWV
The Advant Controller 450 is a flexible system offered in several variants with respect to,
for example, redundancy, power supply, cabinetry, marshalling, and so on. You can find general
information regarding principles and capabilities in this manual, but no details of the different
product packages are included. Please refer to relevant tendering and sales documentation for
that information.
 *HQHUDO6\VWHP8WLOLWLHV
 &38
The central processing unit of the Advant Controller 450 comes in two versions with 8 or 16
Mbyte dynamic RAM. The versions are both designated Processor Module PM511V. A label on
module side states the RAM size (PM511V or PM511V). A Processor Module is built up
around a microprocessor, Motorola 68040, running at 25 MHz.
In this Users Guide the generic name PM511 is used all through.
On the module front, you can see indicators and a character display for high level system
diagnostics. The main operable equipment is a four-position rotary switch for start and
operating mode selection and a restart push button. See Chapter 4, Runtime Operation for more
information on these functions.
The module front also includes a program card interface and a connection for S100 I/O bus
communication.
You can connect a configuration and maintenance tool on the module front.

Table of Contents

Other manuals for ABB Advant Controller 450

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB Advant Controller 450 and is the answer not in the manual?

ABB Advant Controller 450 Specifications

General IconGeneral
BrandABB
ModelAdvant Controller 450
CategoryController
LanguageEnglish

Related product manuals