The DCS550
3ADW000379R0501 DCS550 Manual e e
Environmental Conditions
The technical data contain the technical specifications of the drive, e.g. the ratings, sizes and technical
requirements, provisions for fulfilling the requirements for CE and other markings and warranty policy.
System connection
Environmental limit values
Voltage, 3-phase:
230 to 525 V acc. to IEC 60038
Permissible cooling air temperature
Voltage deviation:
±10 % continuous; ±15 % short-
time (0.5 to 30 cycles)
with rated DC current (forced
ventilation):
0 to +40°C
Rated frequency:
50 Hz or 60 Hz
with different DC current see
figure below:
+30 to +55°C
Static frequency deviation:
50 Hz ±2 %; 60 Hz ±2 %
Dynamic: frequency range:
50 Hz: ±5 Hz; 60 Hz: ± 5 Hz
for options:
0 to +40°C
df/dt:
17 % / s
Relative humidity (at 5...+40°C):
5 to 95 %, no condensation
Note:
Special consideration must
be taken for voltage deviation in
regenerative mode.
Relative humidity (at 0...+5°C):
5 to 50 %, no condensation
Change of the ambient temp.
< 0.5°C / minute
Storage temperature:
-40 to +55°C
Degree of protection
Transport temperature:
-40 to +70°C
Converter modules and
options (line chokes, fuses,
field exciters, etc.):
IP 00 / NEMA TYPE OPEN
Pollution degree (IEC 60664-1,
IEC 60439-1):
2
Vibration class:
3M3
Site elevation
Paint finish
<1000 m above mean sea level:
100%, without current reduction
Converter modules:
Dark grey RAL 7012
>1000 m above mean sea level:
with current reduction, see figure
below
Effect of the site elevation above sea level on the converter’s load
capacity:
Effect of the ambient temperature on the converter module load
capacity:
Current reduction to (%)
Current reduction to (%) for converter modules
Size
Sound pressure level
LP (1 m distance)
Vibration
Shock
Transport in
original Package
Short circuit withstand rating
The DCS
550 is suitable for use in a circuit
capable of delivering not more than:
F1
55 dBA
1.5 mm, 2 - 9 Hz
0.5 g, 9
- 200 Hz
7 g / 22 ms
1.2 m
65 kA rms symmetrical ampere at a maximum
of 600 V
AC
F2
55 dBA
F3
60 dBA
1.0 m
F4
66 - 70 dBA,
depending on fan

Table of Contents