188 
   
 
Signal and parameter list
 
3ADW000379R0501 DCS550 Manual e e 
10.33 DI9Invert (invert digital input 9) 
Inversion selection for digital input 9:
 
Direct  only available with digital extension board 
Inverted  only available with digital extension board 
Int. Scaling:  1 == 1   Type:  C  Volatile:  N 
10.34 DI10Invert (invert digital input 10) 
Inversion selection for digital input
 10: 
Direct  only available with digital extension board 
Inverted only available with digital extension board 
Int. Scaling:  1 == 1   Type:  C  Volatile:  N 
10.35 DI11Invert (invert digital input 11) 
Inversion selection for digital input 11:
 
Direct  only available with digital extension board 
Inverted only available with digital extension board 
Int. Scaling:  1 == 1   Type:  C  Volatile:  N 
Group 11: Speed reference inputs 
11.02 Ref1Mux (speed reference 1 selector/multiplexer) 
Speed reference 1 selector:
 
Open    switch for speed ref. 1 is fixed open 
Close    switch for speed ref 1 is fixed closed, default 
DI1    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI2    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI3    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI4    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI5    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI6    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI7    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI8    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0 
DI9    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; only 
available with digital extension board 
DI10    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; only 
available with digital extension board 
DI11    1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; only 
available with digital extension board 
MCW Bit11  1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; 
MainCtrlWord (7.01) bit 11 
MCW Bit12  1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; 
MainCtrlWord (7.01) bit 12 
MCW Bit13  1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; 
MainCtrlWord (7.01) bit 13 
MCW Bit14  1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; 
MainCtrlWord (7.01) bit 14 
MCW Bit15  1= switch is closed, speed ref 1 is active; 0 = switch is open, speed ref = 0; 
MainCtrlWord (7.01) bit 15 
Int. Scaling:  1 == 1   Type:  C  Volatile:  N