EasyManua.ls Logo

ABB DCS550 - Page 187

ABB DCS550
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
187
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
Signal / Parameter name
min.
max.
def.
unit
10.22 DynBrakeAck (dynamic braking acknowledge)
The drive sets
A105 DynBrakeAck [AlarmWord1 (9.06) bit 4] if a digital input for dynamic braking is selected
and the acknowledge (dynamic braking active) is still present when
On [UsedMCW (7.04) bit 3] is set.
Selections see
MainContAck (10.21).
A105 DynBrakeAck
[AlarmWord1 (9.06)
bit 4] should prevent the drive to be started while dynamic braking is
active.
Int. Scaling: 1 == 1 Type: C Volatile: N
NotUsed
DI11
NotUsed
-
10.23 DC BreakAck (DC breaker acknowledge)
The drive sets
A103 DC BreakAck [AlarmWord1 (9.06) bit 2] if a digital input for the DC-breaker is selected
and the acknowledge is mi
ssing. Selections see MainContAck (10.21).
The motor will coast if
A103 DC BreakAck [AlarmWord1 (9.06) bit 2] is set.
Int. Scaling: 1 == 1 Type: C Volatile: N
NotUsed
DI11
NotUsed
-
10.24 Unused
10.25 DI1Invert (invert digital input 1)
Inversion selection for digital input 1:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-
10.26 DI2Invert (invert digital input 2)
Inversion selection for digital input 2:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-
10.27 DI3Invert (invert digital input 3)
Inversion selection for digital input 3:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-
10.28 DI4Invert (invert digital input 4)
Inversion
selection for digital input 4:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-
10.29 DI5Invert (invert digital input 5)
Inversion selection for digital input 5:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-
10.30 DI6Invert (invert digital input 6)
Inversion selection for digital input 6:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-
10.31 DI7Invert (invert digital input 7)
Inversion selection for digital input 7:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-
10.32 DI8Invert (invert digital input 8)
Inversion selection for digital input 8:
0 =
Direct
1 =
Inverted
Int. Scaling: 1 == 1 Type: C Volatile: N
Direct
Inverted
Direct
-

Table of Contents

Related product manuals