97.25 EMF ActFiltTime (actual EMF filter time)
EMF actual filter tim
e constant for EMF VoltActRel (1.17). Is used for the EMF controller and the EMF feed
Int. Scaling: 1 == 1 ms Type: I Volatile: N
98.02 CommModule (communication modules)
For the communication modules following selections are available:
NotUsed no communication used, default
Fieldbus The drive communicates with the overriding control via an R-type fieldbus adapter
connected in option slot 1. This choice is not valid for the Modbus.
Modbus The drive communicates with the overriding control via the Modbus (RMBA-xx)
connected in option slot 1.
To ensure proper connection and communication of the communication
modules with the SDCS-CON-F use
the screws included in the scope of delivery.
Int. Scaling: 1 == 1 Type: C Volatile: N