196
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
13.27 ConvModeAI6 (conversion mode analog input 6)
The distinction between
bipolar and unipolar respectively voltage and current is done via DIP-switches on the
-01 board:
10V Bi -10 V to 10 V / -20 mA to 20 mA bipolar input, default
0V-10V Uni 0 V to 10 V / 0 mA to 20 mA unipolar input
2V-10V Uni 2 V to 10 V / 4 mA to 20 mA unipolar input
5V Offset 5 V / 10 mA offset in the range 0 V to 10 V / 0 mA to 20 mA for testing or indication of
bipolar signals (e.g. torque, speed, etc.)
6V Offset 6 V / 12 mA offset in the range 2 V to 10 V / 4 mA to 20 mA for testing or indication of
bipolar signals (e.g. torque, speed, etc.)
Int. Scaling: 1 == 1 Type: C Volatile: N
10V Bi
Group 14: Digital outputs
14.01 DO1Index (digital output 1 index)
Digital output 1 is controlled by a selectable bit
- see DO1BitNo (14.02) - of the source (signal/parameter)
selected with this parameter. The format is
-xxyy, with: - = invert digital output, xx = group and yy = index.
If DO1Index (14.01) = 801 (main status word) and DO1BitNo (14.02) = 1 (RdyRun) digital output 1 is high
when the drive is RdyRun.
If DO1Index (14.01) = -801 (main status word) and DO1BitNo (14.02) = 3 (Tripped
) digital output 1 is high
when the drive is not faulty.
utput 1 default setting is: command FansOn CurCtrlStat1 (6.03) bit 0.
Int. Scaling: 1 == 1 Type: SI Volatile: N
14.02 DO1BitNo (digital output 1 bit number)
Bit number of the signal/parameter selected with
DO1Index (14.02).
Int. Scaling: 1 == 1 Type: I Volatile: N
14.03 DO2Index (digital output 2 index)
Digital output 2 is controlled by a selectable bit
- see DO2BitNo (14.04) - of the source (signal/parameter)
selected with this parameter.
The format is -xxyy, with: - = invert digital output, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: SI Volatile: N
14.04 DO2BitNo (digital output 2 bit number)
Bit number of the signal/parameter selected with
DO2Index (14.03).
Int. Scaling: 1 == 1 Type: I Volatile: N
14.05 DO3Index (digital output 3 index)
Digital output 3 is controlled by a selectable bit
- see DO3BitNo (14.06) - of the source (signal/parameter)
arameter. The format is -xxyy, with: - = invert digital output, xx = group and yy = index.
Digital output 3 default setting is: command
MainContactorOn CurCtrlStat1 (6.03) bit 7.
Int. Scaling: 1 == 1 Type: SI Volatile: N
14.06 DO3BitNo (digital output 3 bit number)
Bit number of the signal/parameter selected with
DO3Index (14.05).
Int. Scaling: 1 == 1 Type: I Volatile: N
14.07 DO4Index (digital output 4 index)
Digital output 4 is controlled by a selectable bit
- see DO4BitNo (14.08) - of the source (signal/parameter)
selected with this parameter. The format is
-xxyy, with: - = invert digital output, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: SI Volatile: N
14.08 DO4BitNo (digital output 4 bit number)
Bit number of the signal/parameter selected with
DO4Index (14.07).
Int. Scaling: 1 == 1 Type: I Volatile: N
14.15 DO8Index (digital output 8 index)
Digital output 8 is controlled by a selectable bit
- see DO8BitNo (14.16) - of the source (signal/parameter)
selected with this parameter. The format is
-xxyy, with: - = invert digital output, xx = group and yy = index.
Digital output 8 default setting is: command
MainContactorOn CurCtrlStat1 (6.03) bit 7
Int. Scaling: 1 == 1 Type: SI Volatile: N