165
Signal and parameter list
3ADW000379R0501 DCS550 Manual e e
5.05 AI3 Val (analog input 3 value)
Measured actual voltage at analog input 3. The integer scaling may differ, depending on the connected
hardware and jumper settings.
Int. Scaling: 1000 == 1 V Type: SI Volatile: Y
5.06 AI4 Val (analog input 4 value)
Measured actual voltage at analog input 4. The integer scaling may differ, depending on the connected
hardware and jumper settings.
Int. Scaling: 1000 == 1 V Type: SI Volatile: Y
5.07 AI5 Val (analog input 5 value)
Measured actual voltage at analog input 5. The integer scaling may differ, depending on the connected
hardware and DIP
-switch settings.
Available only with RAIO extension module see
AIO ExtModule (98.06).
Int. Scaling: 1000 == 1 V Type: SI Volatile: Y
5.08 AI6 Val (analog input 6 value)
Measured actual voltage at analog input 6. The integer scaling may differ, depending on the connected
hardware and DIP
-switch settings.
Available only with RAIO extension module see
AIO ExtModule (98.06).
Int. Scaling: 1000 == 1 V Type: SI Volatile: Y
5.11 AO1 Val (analog output 1 value)
Measured actual voltage at analog output
1.
Int. Scaling: 1000 == 1 V Type: SI Volatile: Y
5.12 AO2 Val (analog output 2 value)
Measured actual voltage at analog output 2.
Int. Scaling: 1000 == 1 V Type: SI Volatile: Y
5.15 AI1 ValScaled (analog input 1 scaled value)
Internally scaled value of analog input 1. Depending on setting of
AI1HighVal (13.01) and AI1LowVal (13.02).
AI1HighVal (13.01) = AI1LowVal (13.02) = 4,000 mV gives a value of 250 % when AI1 = 10 V.
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
5.16 AI2 ValScaled (analog input 2 scaled value)
Internally scaled value of analog input 2. Depending on setting of
AI2HighVal (13.05) and AI2LowVal (13.06).
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
5.17 AI3 ValScaled (analog input 3 scaled value)
Internally scaled value of analog input 3. Depending on setting of
AI3HighVal (13.09) and AI3LowVal (13.10).
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
5.18 AI4 ValScaled (analog input 4 scaled value)
Internally scaled value of analog input 4. Depending on setting of
AI4HighVal (13.13) and AI4LowVal (13.14).
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
5.19 AI5 ValScaled (analog input 5 scaled value)
Internally scaled value of analog input 5. Depending on setting of
AI5HighVal (13.21) and AI5LowVal (13.22).
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
5.20 AI6 ValScaled (analog input 6 scaled value)
Internally scaled value of analog input 6. Depending on setting of
AI6HighVal (13.25) and AI6LowVal (13.26).
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
Group 6: Drive logic signals
6.01 SystemTime (converter system time)
Shows the time of the converter in minutes. The system time can be either set by means of
SetSystemTime
or via the DCS Control Panel.
Int. Scaling: 1 == 1 min Type: I Volatile: Y
6.03 CurCtrlStat1 (1
st
current controller status)