258
Signal and parameter list
Signal / Parameter name
min.
max.
def.
unit
86.13 Block13Out (block 13 output)
The value of function block 13 output [
Block1Output (84.81)] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals
SpeedRef (23.01)].
The format is
-xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: I Volatile: N
-9999
9999
0
-
86.14 Block14Out (block 14 output)
The value of function block 14 output [
Block1Output (84.87)] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals
SpeedRef (23.01)].
The format is
-xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: I Volatile: N
-9999
9999
0
-
86.15 Block15Out (block 15 output)
The value of function block 15 output [
Block1Output (84.93)] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals
SpeedRef (23.01)].
The format is
-xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: I Volatile: N
-9999
9999
0
-
86.16 Block16Out (block 16 output)
The value of function block 16 output [
Block16Output (84.99)
] is written to a sink (signal/parameter) by means
of this index pointer [e.g. 2301 equals
SpeedRef (23.01)].
The format is
-xxyy, with: - = negate signal/parameter, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: I Volatile: N
-9999
9999
0
-
Group 88: Internal
This parameter group contains internal variables and should not be changed by the user
88.01 - 88.24 Reserved
88.25 M1TachMaxSpeed (maximum tacho speed)
Internally used maximum tacho speed. This value is depending on the analog tacho output voltage
-
e.g. 60 V
at 1000 rpm
- and the maximum speed of the drive system - which is the maximum of SpeedScaleAct (2.29),
M1OvrSpeed (30.16)
and M1BaseSpeed (99.04).
This value should only be written to by:
tacho fine tuning via ServiceMode (99.06) = SpdFbAssist,
via M1TachVolt1000 (50.13),
TachoAdjust block in AP and
parameter download
Internally limited from:
rpmtorpm
20000
32767
*)29.2(
20000
32767
*)29.
2(
Int. Scaling: (2.29) Type: SI Volatile: N
0
10000
0
rpm
88.26 Reserved
88.27 M1TachoTune (tacho tuning factor)
Internally used tacho fine tuning factor. This value should only be written to by:
tacho fine tuning via ServiceMode (99.06) = SpdFbAssist,
TachoAdjust block in AP and
parameter download
Int. Scaling: 1000 == 1 Type: I Volatile: N
0.3
3
1
-
88.28 Reserved
88.29 M1TachoGain (tacho tuning gain)
Internally used tacho gain tuning. This value should only be written to by:
tacho gain tuning via ServiceMode (99.06) = SpdFbAssist,
M1TachoVolt1000 (50.13) and
parameter download
Int. Scaling: 1 == 1 Type: I Volatile: N
0
15
15
-
88.30 Reserved

Table of Contents