Signal and parameter list
Signal / Parameter name
min.
max.
def.
unit
2.22 TorqUsedMax (used torque maximum)
Relative positive torque limit in percent of
MotNomTorque (4.23). Selected with:
TorqUsedMaxSel (20.18)
Connected to torque limiter after TorqRef4 (2.11).
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
-
-
-
%
2.23 TorqUsedMin (used torque minimum)
Relative negative torque limit in percent of
MotNomTorque (4.23). Selected with:
TorqUsedMinSel (20.19)
Connected to torque limiter after TorqRef4 (2.11).
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
-
-
-
%
2.24 TorqRefExt (external torque reference)
Relative external torque reference value in percent of
MotNomTorque (4.23)
after torque reference A selector:
TorqRefA (25.01) and
TorqRefA Sel (25.10)
Int. Scaling: 100 == 1 % Type: SI Volatile: Y
-
-
-
%
2.25 Unused
2.26 TorqLimAct (actual used torque limit)
Shows parameter number of the actual active torque limit:
0 =
0 no limitation active
1 =
2.19 TorqMaxAll (2.19) is active, includes current limits and field weakening
2 =
2.20 TorqMinAll (2.20) is active, includes current limits and field weakening
3 =
2.22 TorqUsedMax (2.22) selected torque limit is active
4 =
2.23 TorqUsedMin (2.23) selected torque limit is active
5 =
20.07 TorqMaxSPC (20.07) speed controller limit is active
6
= 20.08 TorqMinSPC (20.08) speed controller limit is active
7 =
20.09 TorqMaxTref (20.09) external reference limit is active
8 =
20.10 TorqMinTref (20.10) external reference limit is active
9 =
20.22 TorqGenMax (20.22) regenerating limit is active
10 =
20.24 IndepTorqMaxSPC (20.24) independent speed controller limit is active
11 =
20.25 IndepTorqMinSPC (20.25) independent speed controller limit is active
12 =
2.08 TorqRef1 (2.08) limits TorqRef2 (2.09), see also TorqSel (26.01)
Int. Scaling: 1 == 1 Type: C Volatile: Y
-
-
-
-
2.27 - 2.28 Unused
2.29 SpeedScaleAct (actual used speed scaling)
The value of
SpeedScaleAct (2.29) equals 20,000 internal speed units. Thus follows 20,000 speed units ==
M1SpeedScale (50.01
), in case M1SpeedScale (50.01) 10 or 20,000 speed units == maximum absolute
value of
M1SpeedMin (20.01) and M1SpeedMax (20.02), in case M1SpeedScale (50.01) < 10.
Mathematically speaking:
If
(50.01) 10 then 20,000 == (50.01) in rpm
If
(50.01) < 10 then 20,000 == Max [|(20.01)|, |(20.02)|] in rpm
Int. Scaling: 1 == 1 rpm Type: SI Volatile: Y
-
-
-
rpm
2.30 SpeedRefExt1 (external speed reference 1)
External speed reference 1 after reference 1 multiplexer:
Ref1Mux (11.02)
Int. Scaling: (2.29) Type: SI Volatile: Y
-
-
-
rpm