176
Signal and parameter list
Signal / Parameter name
min.
max.
def.
unit
B9-10 reserved
B11
APAlarm1 A301 4 AP alarm 1
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
B12
APAlarm2 A302 4 AP alarm 2
B13
APAlarm3 A303 4 AP alarm 3
B14
APAlarm4 A304 4 AP alarm 4
B15
APAlarm5 A305 4 AP alarm 5
Int. Scaling: 1 == 1 Type: I Volatile: Y
9.09 Unused
9.10 SysFaultWord (system fault word)
Operating system faults from SDCS
-COM-8 board:
Bit
Fault text Fault code F
B0
Factory macro parameter file error default parameters are invalid
B1
User macro parameter file error one of the User macros is invalid
B2
Non volatile operating system error AMCOS fault, please contact Your local ABB agent
B3
File error in flash problems when writing to the flash memory, please try again
-----------------------------------------------------------------------------------------------------------------------------
-------------------------------------
B4
Internal time level T2 overflow (100 µs) timeout of task T2, if happens frequently please contact Your
local ABB agent
B5
Internal time level T3 overflow (1 ms) timeout of task T3, if happens frequently please contact Your
local ABB agent
B6
Internal time level T4 overflow (50 ms) timeout of task T4, if happens frequently please contact Your
local ABB agent
B7
Internal time level T5 overflow (1 s) timeout of task T5, if happens frequently please contact Your
local ABB agent
-----------------------------------------------------------------
-------------------------------------------------------------------------------------------------
B8
State overflow timeout of task State, if happens frequently please contact Your
local ABB agent
B9
Application window ending overflow application on SDCS-COM-8 faulty
B10
Application program overflow application on SDCS-COM-8 faulty
B11
Illegal instruction crash of CPU due to EMC or hardware problems
------------------------------------------------------------------------------------------------
------------------------------------------------------------------
B12
Register stack overflow overflow due to EMC or firmware bug
B13
System stack overflow overflow due to EMC or firmware bug
B14
System stack underflow underflow due to crash of CPU or firmware bug
B15
reserved
Int. Scaling: 1 == 1 Type: I Volatile: Y
9.11 Diagnosis (diagnosis)
Attention:
Diagnosis (9.11)
is set to zero by means of Reset.
Displays diagnostics messages:
0 =
no message
Firmware:
1 =
default setting of parameters wrong
2 =
parameter flash image too small for all parameters
3 =
reserved
4 =
illegal write attempt on a signal or write-protected parameter, e.g. writing on UsedMCW (7.04)
5 =
reserved
6 =
wrong type code
7 =
an un-initialized interrupted has occurred
8, 9 =
reserved
10 =
wrong parameter value
Autotuning:
11 =
autotuning aborted by fault or removing the Run command [UsedMCW (7.04) bit 3]
12 =
autotuning timeout, Run command [UsedMCW (7.04) bit 3] is not set in time
13 = motor is still turning, no speed zero indication