Signal and parameter list
Signal / Parameter name
min.
max.
def.
unit
15.09 FilterAO2 (filter analog output 2)
Analog output 2
filter time.
Int. Scaling: 1 == 1 ms Type: I Volatile: N
0
10000
0
ms
15.10 ScaleAO2 (scaling analog output 2)
100 % of the signal/parameter selected with
IndexAO2 (15.06) is scaled to the voltage in ScaleAO2 (15.10).
Int. Scaling: 1 == 1 mV Type: I Volatile: N
0
10000
10000
mV
15.11 IndexAO3 (analog output 3 index)
Analog output 3 is controlled by a source (signal/parameter) selected with
IndexAO3 (15.11). The format is -
xxyy
, with: - = negate analog output, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: SI Volatile: N
-9999
9999
-
-
15.12 CtrlWordAO3 (control word analog output 3
Analog output 3 can be written to via
CtrlWordAO3 (15.12) using AP or overriding control if IndexAO3 (15.11)
is set to zero
. Further description see group 19 Data Storage.
Int. Scaling: 1 == 1 Type: SI Volatile: Y
-32768
32767
0
-
15.13 ConvModeAO3 (convert mode analog output 3)
Analog output 3 signal offset:
0 =
0mA-20mA Uni 0 mA to 20 mA unipolar output
1 =
4mA-20mA Uni 4 mA to 20 mA unipolar output, default
2 =
10mA Offset 10 mA offset in the range 0 mA to 20 mA for testing or indication of bipolar signals (e.g.
torque, speed, etc.)
3 =
12mA Offset 12 mA offset in the range 4 mA to 20 mA for testing or indication of bipolar signals (e.g.
torque, speed, etc.)
4 =
0mA-20mA Abs absolute 0 mA to 20 mA unipolar output (negative values are shown positive)
Int. Scaling: 1 == 1 Type: C Volatile: N
4mA-20mA Uni
0mA-20mA Abs
4mA-20mA Uni
-
15.14 FilterAO3 (filter analog output 3)
Analog output 3 filter time.
Int. Scaling: 1 == 1 ms Type: I Volatile: N
0
10000
0
ms
15.15 ScaleAO3 (scaling analog output 3)
100 % of the signal/parameter selected with
IndexAO3 (15.11) is scaled to the current in ScaleAO3 (15.15).
Int. Scaling: 1 == 1 Type: I Volatile: N
0
20
20
mA
15.16 IndexAO4 (analog output 4 index)
Analog output 4 is controlled by a source (signal/parameter) selected with
IndexAO4 (15.16). The format is -
xxyy
, with: - = negate analog output, xx = group and yy = index.
Int. Scaling: 1 == 1 Type: SI Volatile: N
-9999
9999
15.17 CtrlWordAO4 (control word analog output 4)
Analog output 4 can be written to via
CtrlWordAO4 (15.17) using AP or overriding control if IndexAO4 (15.17)
is set to zero
. Further description see group 19 Data Storage.
Int. Scaling: 1 == 1 Type: SI Volatile: Y
-32768
32767
0
-
15.18 ConvModeAO4 (convert mode analog output 4)
Analog output 4 signal offset:
0 =
0mA-20mA Uni 0 mA to 20 mA unipolar output
1 =
4mA-20mA Uni 4 mA to 20 mA unipolar output, default
2 =
10mA Offset 10 mA offset in the range 0 mA to 20 mA for testing or indication of bipolar signals (e.g.
torque, speed, etc.)
3 =
12mA Offset 12 mA offset in the range 4 mA to 20 mA for testing or indication of bipolar signals (e.g.
torque, speed, etc.)
4 =
0mA-20mA Abs absolute 0 mA to 20 mA unipolar output (negative values are shown positive)
Int. Scaling: 1 == 1 Type: C Volatile: N
4mA-20mA Uni
0mA-20mA Abs
4mA-20mA Uni
-
15.19 FilterAO4 (filter analog output 4)
Analog output 4 filter time.
Int. Scaling: 1 == 1 ms Type: I Volatile: N
0
10000
0
ms
15.20 ScaleAO4 (scaling analog output 4)
100 % of the signal/parameter selected with
IndexAO4 (15.16) is scaled to the current in ScaleAO4 (15.20).
Int. Scaling: 1 == 1 Type: I Volatile: N
0
20
20
mA