NoteAction
xx0800000335
Remove the bracket fitted on the tubular
shaft unit.
10
Parts:
• A: Tubular shaft unit
• B: Attachment screws M6x16 qual-
ity 8.8-A2F (2 pcs)
• C: Bracket
Remove the signal lamp, if used.11
xx0800000338
Remove the cable bracket on the armhouse.12
Parts:
• A: Signal lamp
• B: Bracket
• C: Cable bracket
Using caution, pull the cable package out
of the hole where the cable bracket was fit-
ted.
13
Stop the air from the Foundry Prime air
hose. Insert a screw in the hose and a lock
it with a hose clamp.
14
Continues on next page
Product manual - IRB 4600 Foundry Prime 271
3HAC040585-001 Revision: M
© Copyright 2013-2018 ABB. All rights reserved.
4 Repair
4.4.1 Replacing the complete upper arm
Continued