NoteAction
For art. no. see:
• Additional equipment - Foundry
Prime on page 314
xx1000000631
Apply Loctite 577 in the attachment holes
of the cover.
23
• A: Loctite 577 in holes (4 pcs)
If the balancing device is reused, check
that the gasket on the cover is not dam-
aged.
24
Fit the old cover with the air nipple25
For art. no. see:
• Additional equipment - Foundry
Prime on page 314
xx1000000632
Apply rust preventive (Mercasol) around
the edge of the cover as a protection of
the broken paint layers.
26
• A: Mercasol
xx0900000090
Fill the cradle bearings with 70 ml, Optimol
PDO.
Note
The inner hole is used for lubrication.
The outer hole is used for air outlet.
27
Continues on next page
Product manual - IRB 6640 Foundry Prime 325
3HAC040586-001 Revision: N
© Copyright 2011-2018 ABB. All rights reserved.
4 Repair
4.5.4.2 Replacing balancing device (design 2)
Continued