9: Performance Assurance Agent
Minimum: 1
Maximum: (One-way join period / Sampling period)
Join average delay threshold
Purpose
Define the maximum join average delay.
Validity
UDP sink probe configured with a multicast destination address.
Values (in milliseconds)
Minimum: 100ms
Maximum: One-way join period
Maximum leave delay
Purpose
Defines the maximum leave delay objective.
Validity
UDP sink probe configured with a multicast destination address.
Values (in milliseconds)
0 (default): No IGMP measurement
Minimum: 100ms
Maximum: (One-way reference period - One-way join period)
Leave delay threshold
Purpose
Defines the maximum consecutives leave delay samples allowed greater than the maximum leave delay.
Validity
UDP sink probe configured with a multicast destination address.
Values (in samples)
Minimum: 1
Maximum: (One-way reference period - One-way join period) / Sampling period
Leave average delay threshold
Purpose
Define the maximum leave average delay.
Validity
UDP sink probe configured with a multicast destination address.
Values (in milliseconds)
Minimum: 100ms
Maximum: (One-way reference period - One-way join period)