3: Management & Configuration
SNMP trap receivers parameters
Type
Type of SNMP Trap receivers. SNMPv1 / SNMPv2c
ID
ID number of the trap receiver.
State
If Enabled the unit will send SNMPv1 or SNMPv2c traps to a specified notification receiver.
UDP port
The UDP port that the unit will use to send traps to the notification receiver. By default, the well-known SNMP trap port
(162) is used.
Host name
The IP address or host name of the device that will receive SNMP traps (and/or inform notifications). The unit sends a
Cold Start trap when it starts up.
Community
The community string required to send traps to the notification receiver.
2. Click on the ID to configure each trap receiver.