EasyManua.ls Logo

Advanced Energy Pinnacle Plus+ - Page 118

Advanced Energy Pinnacle Plus+
204 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4-74 I/O Communication and Control 5702269-C
Advanced Energy
®
59
joule recipe
repetition
Send 2 data bytes (16-bit value). Valid input
for the joule recipe repetitions are 1 through
65535.
Note: This command is only valid when you
set the continuous joule recipe type.
Readback this value with command 233.
2 CSR only
61
enable/
disable micro
arc handling
Enables or disables micro arc handling feature.
Hard arc handling is always enabled.
Send 1 data byte (8-bit value):
•0 = Disable
Non-zero = Enable
Note: Cycling power to the unit resets arc
handling mode to enabled.
Read this value with command 163.
1 CSR codes:
0,1
64
threshold
type
Sets the joule mode counter threshold type.
Send one data byte (8-bit value):
0 = Power
•1 = Voltage
•2 = Current
Read back this setting with command 163.
1 CSR codes:
0,1,2,4,9
65
pulsing
enabled
mode
Enables pulsing at the current threshold
(default setting) or always.
Note: Frequency is limited to 150 kHz when
the pulse mode is set to be enabled
always.
Send one data byte (8-bit value):
0 = Pulsing enabled at current threshold
1 = Pulsing enabled always
Read back this setting with command 163.
1 CSR codes:
0,1,2,4,9
Table 4-19. AE Bus Commands (Continued)
Command Description Number
of
Transmit
Data
Bytes
CSR
Codes or
Number of
Response
Bytes
Page 118 of 204
Ex. 1024 Page 118

Table of Contents