5702269-C I/O Communication and Control 4-79
Pinnacle™ Plus+ 10 kW
141
request user
power limit
Requests the output power limit. Accuracy is
+0.3% of the full rated output voltage for the
supply.
The returning packet contains 2 data bytes (16-
bit value) indicating the limit in kilowatts. The
value implies 3 decimal places for a stand-
alone unit (5000 = 5.000 kW) and 2 decimal
places are implied for a master/slave unit
(2000 = 20.00 kW).
This value is set with command 49.
02
142
request user
voltage limit
Requests the output voltage limit. Accuracy is
+0.3% of the full rated output voltage for the
supply.
The returning packet contains 2 data bytes (16-
bit value) indicating the limit in voltage.
This value is set with command 50.
02
143
request user
current limit
Requests the output current limit. Accuracy is
+0.3% of the full rated output current for the
supply.
The returning packet contains 2 data bytes (16-
bit value) indicating the limit in amperes.
Assume 2 decimal places (5000 = 50.00 A).
This value is set with command 51.
02
146
request pulse
frequency
index
Requests pulse frequency index (read in 5 kHz
increments); the returning packet contains 1
byte:
• 0 = 0 kHz (pulsing disabled)
•1 = 5 kHz
• 2 = 10 kHz
• 3 = 15 kHz
• 4 to 69 = (follow the established pattern)
• 70 = 350 kHz
This value is set with command 92.
01
Table 4-19. AE Bus Commands (Continued)
Command Description Number
of
Transmit
Data
Bytes
CSR
Codes or
Number of
Response
Bytes