EasyManuals Logo

Agilent Technologies Truevolt Series User Manual

Agilent Technologies Truevolt Series
352 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #25 background imageLoading...
Page #25 background image
Subnet Mask
Subnetting allows the LAN administrator to subdivide a network to simplify administration and minimize network
traffic. The subnet mask indicates the portion of the host address used to indicate the subnet.
l Contact your LAN administrator for details.
l This setting is non-volatile; it will not be changed by power cycling or *RST.
l Front Panel:[Utility] > I/O Config > LAN Settings > Modify Settings
Then set the first softkey to Manual and press Subnet Mask to enter a new subnet mask with the arrow keys
(for example: 255.255.0.0).
l SCPI: SYSTem:COMMunicate:LAN:SMASk "<mask>"
l If you change this parameter, you must either press the Apply Changes softkey (front panel) or send
SYSTem:COMMunicate:LAN:UPDate (remote interface) for the change to take effect.
Default Gateway
A gateway is a network device that connects networks. The default gateway setting is the IP address of such a device.
l You need not set a gateway address if using DHCP.
l Contact your LAN administrator for details.
l This setting is non-volatile; it will not be changed by power cycling or *RST.
l Front Panel:[Utility] > I/O Config > LAN Settings > Modify Settings
Then set the first softkey to Manual and press More and Gateway. Then set the appropriate gateway address
using the arrow keys.
l SCPI: SYSTem:COMMunicate:LAN:GATeway "<address>"
l If you change this parameter, you must either press the Apply Changes softkey (front panel) or send
SYSTem:COMMunicate:LAN:UPDate (remote interface) for the change to take effect.
Hostname
A hostname is the host portion of the domain name, which is translated into an IP address.
l The instrument receives a unique hostname at the factory, but you may change it. The hostname must be unique
on the LAN.
l The name must start with letter; other characters can be an upper or lower case letters, numeric digits, or dashes
("-").
l This setting is non-volatile; it will not be changed by power cycling or *RST.
l Front Panel:[Utility] > I/O Config > LAN Settings > Modify Settings
Then press Host Name and enter the hostname with the front-panel arrow keys.
l SCPI: SYSTem:COMMunicate:LAN:HOSTname "<name>"
l If you change this parameter, you must either press the Apply Changes softkey (front panel) or send
SYSTem:COMMunicate:LAN:UPDate (remote interface) for the change to take effect.
Agilent Truevolt Series DMM Operating and Service Guide 25

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Agilent Technologies Truevolt Series and is the answer not in the manual?

Agilent Technologies Truevolt Series Specifications

General IconGeneral
BrandAgilent Technologies
ModelTruevolt Series
CategoryLaboratory Equipment
LanguageEnglish

Related product manuals