Configure and Start Up the Drive Chapter 4
After the Inertia Tune has completed, 00:76 [Total Inertia] is updated. This
number represents how long it takes to accelerate the Motor being used from 0
RPM to Motor Nameplate RPM speed at 100% motor torque. This test can be
redone after coupling to the machine or calculated and entered into the
parameter from a formal sizing process. Typical values of this parameter range
from 0.1 …2 for most applications.