Electrical Safety Considerations
Environment and Enclosure
IMPORTANT To avoid electrolytic corrosion on the external earth terminal, avoid spraying
moisture directly on the terminal. When used in wash-down environments,
apply a sealant or other corrosion inhibitor on the external ground terminal
to minimize any negative effects of galvanic or electro-chemical corrosion.
Ground connections should be inspected regularly.
IMPORTANT To comply with the CE Low Voltage Directive (LVD), all connections to this
equipment must be powered from a source compliant with the following:
Safety extra low voltage (SELV) Supply
Protected extra low voltage (PELV) Supply
To comply with UL/C-UL requirements, this equipment must be powered
from a source compliant with the following:
IEC 60950-1 Ed. 2.1, Clause 2.2 - SELV Circuits
IMPORTANT This equipment is supplied as enclosed equipment. It should not require an
additional system enclosure when used in locations consistent with the
enclosure type ratings stated in the Environment
on page 20 section of this
publication. Subsequent sections of this publication may contain additional
information regarding specific enclosure type ratings, beyond what this
product provides, that are required to comply with certain product safety
certifications.
In addition to this publication, see the following:
See also the following: NEMA 250 and IEC 60529, as applicable, for
explanations of the degrees of protection provided by enclosures.
IMPORTANT This equipment is not intended for use in residential environments and may
not provide adequate protection to radio communication services in such
environments.
IMPORTANT This equipment is intended for use in overvoltage Category III applications
(as defined in IEC 60664-1), at altitudes up to 2000 m (6562 ft) at the default
carrier frequency without derating. See PowerFlex® 755 On-Machine Drive
Specifications, publication 750-TD003
for altitude and derating information.
At the End of Life, this equipment should be collected separately from any
unsorted municipal waste.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley The PowerFlex 755 On-Machine and is the answer not in the manual?

Allen-Bradley The PowerFlex 755 On-Machine Specifications

General IconGeneral
BrandAllen-Bradley
ModelThe PowerFlex 755 On-Machine
CategoryDC Drives
LanguageEnglish

Related product manuals