136
ML-2050A/2051A/2150A
4. Commands
Resetting the Total Number of Outputs
The command (code: C1) to reset the total number of outputs (SHOT COUNT) is
explained below.
CH1/CH0 Equipment No. (CH1 = tens digit, CH0 = units digit)
ACK or NAK
The Laser accepts the command only when in external communication
control (RS-485 CONTROL) mode. It returns a [NAK] when in any other
control method.
Resetting the Appropriate Number of Outputs
The command (code: C2) to reset the appropriate number of outputs (GOOD
COUNT) is explained below.
CH1/CH0 Equipment No. (CH1 = tens digit, CH0 = units digit)
ACK or NAK
The Laser accepts the command only when in external communication
control (RS-485 CONTROL) mode. It returns a [NAK] when in any other
control method.
Reading Error No. at Occurrence of Trouble
The command (code: RT) to read error No. at occurrence of trouble is explained below.
CH1/CH0 Equipment No. (CH1 = tens digit, CH0 = units digit)