148
ML-2050A/2051A/2150A
2. Maintenance of the Cooler Unit Section
2. Maintenance of the Cooler Unit Section
This section explains how to perform cleaning for the air lter and water lter,
and how to perform maintenance for the ion-exchanger. This section also
explains how to drain water from the cooling water tank and laser chamber,
which is required at another maintenance.
Cleaning the Air Filter
The air lter on the side face of the main unit is provided at the air inlet to the cooler
unit section. Perform cleaning every week.
Item required
Phillips screwdriver
Operating Procedure
(1) Remove the lter retainer from the side on phillips screwdriver.
(2) Take out the lter and wash it in tap water.
⇒
If it is stained badly, use neutral detergent.
(3) Air dry the lter naturally, then re-place it and secure it with the lter retainer.
Side cover radiator
Air lter
Filter retainer