42
ML-2050A/2051A/2150A
2. Preparing Cooling Water
2. Preparing Cooling Water
CAUTION
Use deionized water or puried water for cooling water. Using tap water, industrial
water, ground water, or ultra pure water (Resistivity: 16 MΩ-cm or more) causes
corrosion or clogging, resulting in a failure.
Item required
Cooling water (6 liters), water feed pump
Operating Procedure
(1) Open the front door and remove the lid of the cooling water tank.
(2) Take out the oating panel in the tank.
Take care not to attach dirt onto the oating panel.
(3) Feed cooling water up to the line under the water level label "HIGH" by using the
attached water feed pump.
Use the water feed pump only for cooling water and do not use other uses
including kerosene.
(4) Float the oating panel on the water and install the lid of the cooling water tank
as before.
The oating panel can be repeatedly used. When it is stained, wash it lightly in
tap water with a soft sponge and lastly rinse it in deionized water or puried water
for use.
When the cooler is operated for the rst time after water feeding, the water level
may a little lower. In this case, replenish cooling water again. Before feeding
cooling water, be sure to take out the oating panel.
Status where the front door of the main unit is opened
UPPER LIMIT
LOWER LIMIT
P-1518
Lid
Water level label
Floating panel
Ion-exchanger
Cooling water tank