EasyManua.ls Logo

Amada ML-2050A-CE - Draining Water from the Cooling Water Tank

Amada ML-2050A-CE
195 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2. Maintenance of the Cooler Unit Section
149
ML-2050A/2051A/2150A
Chapter 1 How to Perform Maintenance
Introduction Part
Installation and
Preparation Part
Operating Part Maintenance Part Appendixes
P-1518
LOWER LIMIT
UPPER LIMIT
Draining Water from the Cooling Water Tank
Before replacing the ion-exchange resin for relling, replacing the ion-exchanger, and
replacing cooling water (once every 6 months), drain water from the cooling water
tank to make the tank empty. When moving or transporting the equipment or when
the equipment is stopped for one month or more, make the cooling water tank empty
in advance.
Item required
Water feed pump and bucket
Operating Procedure
(1) Open the front door.
(2) Open the lid of the cooling water tank and take out the oating panel.
Keep the panel clean during the exchanging work.
(3) Pump out water in the tank.
(4) Return the oating panel in the tank. Return and secure the tank lid.
The Laser front (With front door opened)
Lid
Floating panel
Ion-exchanger
Cooling water tank

Table of Contents