152
ML-2050A/2051A/2150A
2. Maintenance of the Cooler Unit Section
3
Installing the Ion-Exchanger
(1) Insert the ion-exchanger and turn it clockwise with the mounting/removing tool.
<Note>
Use the mounting/removing tool for installing the ion-exchanger. If the
mounting/removing tool is too tightened, the thread portion may be broken.
(2) Put cooling water up to the line under HIGH of the water level label with the
attached water feed pump.
(3) Float the oating panel on the water surface in the tank as it was and install the
lid of the cooling water tank.
⇒
The oating panel can be repeatedly used. Because its material is polyethylene
foam, dispose of the oating panel properly.
⇒
If the ion-exchanger is used without the floating panel in the tank, the ion-
exchange resin will be deteriorated more quickly. Be sure to put the floating
panel into the tank.