70
ML-2050A/2051A/2150A
1. Setting Welding Schedules
(2) Press the ENTER key to denitively set the set numeric value.
The set ratio of the upper limit value is registered. If this upper limit value is
exceeded, a prompting screen for replacing the ashlamp is displayed.
When this screen appears, output pin No.9 (upper limit of lamp input) of the external
output signal EXT.I/O (1) connector is open-circuited for output.
Press the TROUBLE RESET key to clear the screen display.
⇒
After the screen display is reset, pin No.9 of the EXT.I/O (1) connector output
remains in an open circuit output state. If the power supply is less than the upper
limit value of lamp input power when the flashlamp lights next time, the open
circuit output state is returned to a closed circuit state. The open circuit output
state is also reset by turning on the power supply again.
WATER 28˚C
LAMP INPUT POWER LIMIT !!
CHECK THE LAMPS !!
(LAMP INPUT PWR 095%)
HV:OFF POSI.BLINK:OFF POSITION:OFF