98
CDC Msg = 1 (Report State)
《Setting item》
(1) Dev Physical Addr Set Physical address of the destination device of the message.
Set HEC Functionality State
0 Not Supported
1 Inactive
2 Active
(2) HEC Func State (0-3)
3 Activation Field
Set Host Functionality State.
0 Not Supported
1 Inactive
(3) Host Func State (0-2)
2 Active
Set ENC Functionality State.
0 Not Supported
1 Inactive
(4) ENC Func State (0-2)
2 Active
Set CDC Error Code.
0 No Error “No Error”
1 Never Support “Initiator does not have the requested
Capability”
2 Can not
respond
“Initiator is not capable to carry out the
request in this state”
(5) CDC Error Code (0-3)
3 Other Error ”Other Error”
《Criteria of result judgment》
After finish sending <CDC_HEC_ReportState>, judge it as PASS.
Note : the setting value of Dev Physical Addr and Physical Address of VG main unit are same (message
destination = VG main unit), the result is FAIL.
Or, if the device set by Dev Physical Addr does not exist, the result is FAIL.